INTEGRATION RELAY INSPECTION

PROCEDURE


  1. INSPECT INTEGRATION RELAY


    1. Inspect the IG2 relay.


      1. A00YNDMC02
        *a

        Component without harness connected

        (Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1L-1 - 1K-4 Auxiliary battery voltage is not applied between terminals 1K-3 and 1K-2 10 kΩ or higher
        1L-1 - 1K-4 Auxiliary battery voltage is applied between terminals 1K-3 and 1K-2 Below 1 Ω

        If the result is not as specified, replace the integration relay.

    2. Inspect the BATT FAN relay.


      1. A00YNDMC02
        *a

        Component without harness connected

        (Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1L-1 - 1K-8 Auxiliary battery voltage is not applied between terminals 1K-7 and 1K-6 10 kΩ or higher
        1L-1 - 1K-8 Auxiliary battery voltage is applied between terminals 1K-7 and 1K-6 Below 1 Ω

        If the result is not as specified, replace the integration relay.

    3. Inspect the EFI-MAIN relay.


      1. A00YNDMC02
        *a

        Component without harness connected

        (Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1L-1 - 1J-4 Auxiliary battery voltage is not applied between terminals 1J-2 and 1J-3 10 kΩ or higher
        1L-1 - 1J-4 Auxiliary battery voltage is applied between terminals 1J-2 and 1J-3 Below 1 Ω

        If the result is not as specified, replace the integration relay.

    4. Inspect the HORN relay.


      1. A00YNDMC02
        *a

        Component without harness connected

        (Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1L-1 - 1J-8 Auxiliary battery voltage is not applied between terminals 1J-6 and 1J-7 10 kΩ or higher
        1L-1 - 1J-8 Auxiliary battery voltage is applied between terminals 1J-6 and 1J-7 Below 1 Ω

        If the result is not as specified, replace the integration relay.