PROCEDURE
INSTALL HEATED OXYGEN SENSOR
| *a | Length of SST 30 mm (1.18 in.) |
| *b | Length of Torque Wrench 300 mm (11.8 in.) |
Using SST, install the heated oxygen sensor to the front exhaust pipe assembly.
Note
If a component has been dropped or subjected to a strong impact, replace it.
Tech Tips
This torque value is effective when SST is parallel to the torque wrench.
The "with SST" torque value is effective when using SST with a fulcrum length of 30 mm (1.18 in.).
The "with SST" torque value is effective when using a fulcrum length of 300 mm (11.8 in.).
If using a torque wrench with a different length, or connecting the torque wrench and SST at an angle, refer to the alternate torque values.
Connect the 3 clamps of the wire harness to install the wire harness clamp bracket.
Install the wire harness clamp bracket with the bolt.
Install the wire harness bracket.
Connect the heated oxygen sensor connector.
INSPECT FOR EXHAUST GAS LEAK
INSTALL FRONT NO. 3 ENGINE UNDER COVER
Install the front No. 3 engine under cover with the 4 clips.