MOTOR CABLE INSTALLATION

PROCEDURE


  1. INSTALL MOTOR CABLE

    CAUTION:

    Wear insulated gloves.


    1. Install the motor cable to the hybrid vehicle transaxle assembly with the 3 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }

      Note

      Keep the sealing surfaces of the motor cable and the connector terminal joint free of foreign matter.

    2. Engage the 2 claws to install a new terminal cap to the hybrid vehicle transaxle assembly.

      Note

      When installing the terminal cap to the motor cable terminal block, keep the sealing surface free of foreign matter.

    3. A00YNWK

      Place the motor cable connector shell in position and install it with the 2 bolts.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    4. Connect the 3 clamps to the wire harness clamp bracket and motor cable bracket.

  2. INSTALL INVERTER TRAY BRACKET

    Click here

  3. INSTALL INVERTER RESERVE TANK ASSEMBLY

    Click here

  4. INSTALL INVERTER WITH CONVERTER ASSEMBLY

    Click here