| DTC Code | DTC Name |
|---|---|
| P282813 | Pressure Control Solenoid "K" Circuit Open |
DESCRIPTION
According to current from the ECM, the shift solenoid valve SLS controls secondary pulley pressure and belt clamping pressure in accordance with the input shaft torque.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P282813 | Pressure Control Solenoid "K" Circuit Open | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Comes on | DTC stored | SAE Code: P282B |
MONITOR DESCRIPTION
This DTC indicates an open or short in the shift solenoid valve SLS circuit. If there is an open or short in the shift solenoid valve SLS circuit, the ECM detects the malfunction, illuminates the MIL and stores this DTC.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Perform the D position test in Road Test.
Check for DTCs again.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)
| *a | Component without harness connected (Transmission Wire) |
Disconnect the B185 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the B185 transmission wire connector.
| Result | |||
|---|---|---|---|
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
Disconnect the B208 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the B208 ECM connector.
| Result | |||
|---|---|---|---|
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM)
REPLACE ECM
Replace the ECM.
| Result | ||
|---|---|---|
|
PERFORM INITIALIZATIONClick here
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly.
| Result | ||
|---|---|---|
|
PERFORM INITIALIZATIONClick here