РЫЧАГ ПЕРЕКЛЮЧЕНИЯ ПЕРЕДАЧ В СБОРЕ ПОВТОРНАЯ СБОРКА

PROCEDURE


  1. INSTALL INDICATOR LIGHT WIRE SUB-ASSEMBLY


    1. A00YB7FC02
      *1 Indicator Light Wire Sub-assembly
      *a Cap
      *b Bulb

      Install the cap to the bulb.

    2. Install the bulb to the indicator light wire sub-assembly.

    3. Connect the indicator light wire sub-assembly connector to the shift lock control unit assembly.

  2. INSTALL SHIFT LOCK RELEASE BUTTON


    1. A00YB1L

      Apply MP grease to the shift lock release button and compression spring.

    2. Install the shift lock release button and compression spring to the shift lock control unit assembly.

  3. INSTALL POSITION INDICATOR SLIDE COVER


    1. A00Y9EA

      Install the position indicator slide cover to the No. 2 position indicator slide cover.

    2. Install the position indicator slide cover to the shift lock control unit assembly.

  4. INSTALL POSITION INDICATOR LIGHT GUIDE


    1. A00Y5TU

      Engage the 4 claws to install the position indicator light guide to the position indicator lower housing.

  5. INSTALL FLOOR SHIFT POSITION INDICATOR HOUSING SUB-ASSEMBLY


    1. A00Y6N7

      Engage the 4 claws to install the floor shift position indicator housing sub-assembly to the position indicator lower housing.

  6. INSTALL POSITION INDICATOR LOWER HOUSING


    1. A00Y8VD

      Engage the 4 claws to install the position indicator lower housing to the shift lock control unit assembly.

    2. Connect the indicator light wire assembly to the position indicator lower housing.