СИСТЕМА МЕХАНИЧЕСКОЙ ТРАНСМИССИИ "MULTIMODE" TC and CG Terminal Circuit

DESCRIPTION

Terminals TC and CG are located in the DLC3. When performing the initialization and learning procedure without using the GTS, connecting terminals TC and CG is necessary. If the TC terminal circuit is open, these calibration procedures cannot be performed without using the GTS.

WIRING DIAGRAM

A01T9Q3E01

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (TCM - DLC3)


    1. Disconnect the TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E104-25 (DG) - E11-13 (TC) Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TC OF DLC3 - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E11-13 (TC) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (CG OF DLC3 - BODY GROUND)


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E11-4 (CG) - Body ground Always Below 1 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. REPLACE TCM


    1. Replace the TCM.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  5. PERFORM INITIALIZATION


    1. Perform the initialization and learning procedure.

      Click here

      Result
      Proceed to
      NEXT