СВЕЧА НАКАЛИВАНИЯ ПРОВЕРКА БЕЗ СНЯТИЯ С АВТОМОБИЛЯ

PROCEDURE


  1. INSPECT GLOW PLUG

    Note

    Turn the ignition switch off for 60 seconds before performing this inspection.


    1. A01XLDT

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Glow plug terminal - Body ground 20°C (68°F)

      Approximately

      1.0 Ω

      Note


      • Do not damage the glow plug pipes as doing so could cause an open circuit or shorten the life of the glow plugs.

      • Prevent oil and gasoline from contacting the glow plugs when cleaning them.

      • During the inspection, be sure to wipe off any oil on the terminal and Bakelite washer with a dry cloth.

      • Do not apply more than 11 V to the glow plug as it could cause an open circuit.