СВЕЧА НАКАЛИВАНИЯ СНЯТИЕ

PROCEDURE


  1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note


    • After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

    • When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  2. REMOVE RESONATOR WITH AIR CLEANER CAP SUB-ASSEMBLY

    Click here

  3. REMOVE INTAKE PIPE

    Click here

  4. DISCONNECT VENTILATION HOSE


    1. B001HOD

      Disconnect the ventilation hose.

  5. REMOVE NO. 1 GLOW PLUG CONNECTOR


    1. B001EFF

      Remove the nut, No. 2 glow plug resistor insulator and washer and disconnect the wire harness.

    2. Remove the 4 screw grommets and 4 nuts.

    3. Remove the No. 1 glow plug connector and No. 1 glow plug resistor insulator.

  6. REMOVE GLOW PLUG ASSEMBLY


    1. B001GPD

      Using a 12 mm deep socket wrench, remove the 4 glow plugs.