ION GENERATOR REMOVAL


  1. REMOVE INSTRUMENT PANEL SAFETY PAD ASSEMBLY

    Click here

  2. REMOVE HEATER TO REGISTER DUCT ASSEMBLY (for LHD)


    1. B000KOO

      Remove the clip.

    2. Remove the 3 screws <C>.

    3. Disengage the heater to register duct assembly from the ion generator assembly, to remove the heater to register duct.

  3. REMOVE HEATER TO REGISTER DUCT ASSEMBLY (for RHD)


    1. B000IP2

      Remove the clip.

    2. Remove the 3 screws <C>.

    3. Disengage the heater to register duct assembly from the ion generator assembly, to remove the heater to register duct.

  4. REMOVE ION GENERATOR SUB-ASSEMBLY WITH BRACKET


    1. B000MQME01
      Text in Illustration
      *A for LHD
      *B for RHD

      Remove the 3 screws and ion generator sub-assembly with bracket.

  5. REMOVE NO. 1 AIR PURIFIER AIR DUCT


    1. B000LVLE01
      Text in Illustration
      *A for LHD
      *B for RHD

      Disengage the 2 claws to remove the No. 1 air purifier air duct.

  6. REMOVE ION GENERATOR SUB-ASSEMBLY


    1. B000KEBE01
      Text in Illustration
      *A for LHD
      *B for RHD

      Remove the 3 screws and ion generator sub-assembly.