AIR CONDITIONING SYSTEM, Diagnostic DTC:B1479/79

DTC Code DTC Name
B1479/79 Flow Sensor Circuit

DESCRIPTION

The A/C flow sensor, which is mounted on the compressor, is used to detect the amount of refrigerant flow. The A/C flow sensor converts the amount of refrigerant flow that is detected to a voltage value to send it to the air conditioning amplifier assembly. The voltage value sent from the A/C flow sensor changes depending on the amount of refrigerant flow. As the amount of refrigerant flow becomes larger, the voltage becomes lower. As the amount of refrigerant flow becomes smaller, the voltage becomes higher. The air conditioning amplifier assembly supplies 5 V to the A/C flow sensor and monitors changes in the voltage value sent from the A/C flow sensor. The air conditioning amplifier assembly then sends a signal to the ECM via CAN communication to allow the ECM to control the engine speed while the air conditioning is on.

DTC No. DTC Detection Condition Trouble Area
B1479/79 Open or short in A/C flow sensor circuit
  • Compressor assembly with pulley (A/C flow sensor)*1

  • Compressor and magnet clutch (A/C flow sensor)*2

  • Harness or connector between compressor assembly with pulley (A/C flow sensor) and air conditioning amplifier assembly*1

  • Harness or connector between compressor and magnet clutch (A/C flow sensor) and air conditioning amplifier assembly*2

  • Air conditioning amplifier assembly


WIRING DIAGRAM

B000N7OE24

INSPECTION PROCEDURE

PROCEDURE


  1. CONFIRM MODEL

    Result
    Result Proceed to
    except 2GR-FE A
    for 2GR-FE B

    B
    A
  2. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. Read the Data List according to the display on the intelligent tester.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Flow Sensor

      A/C flow sensor /

      Min.: 0 V

      Max.: 5 V

      Ignition switch ON: 0.3 to 4.7 V A/C flow sensor is malfunctioning when a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds.
      OK
      The display is as specified in the Normal Condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to Problem Symptoms Table) A
      OK (When troubleshooting according to the DTC (for TMC, TMMR Made)) B
      OK (When troubleshooting according to the DTC (for TMMK Made)) C
      NG D

    B
    C
    D
    A
  3. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. Read the Data List according to the display on the intelligent tester.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      A/C Cutoff Signal

      A/C control cutoff signal /

      OFF or ON

      The ECM sends the air conditioning control cutoff signal displayed -
      Result
      Result Proceed to
      Value in Data List indicates OFF A
      Value in Data List indicates ON B

    B
    A
  4. REPLACE COMPRESSOR ASSEMBLY WITH PULLEY (A/C FLOW SENSOR)


    1. Replace the compressor assembly with pulley (A/C flow sensor) Click here (for 2AR-FE)).

    2. Replace the compressor assembly with pulley (A/C flow sensor) Click here (for 6AR-FSE)).

      Tech Tips

      Since the compressor assembly with pulley (A/C flow sensor) cannot be inspected while it is removed from the vehicle, replace the compressor assembly with pulley (A/C flow sensor) with a new or a known good one and check that the condition returns to normal.

    3. Check for DTCs.

      Result
      Result Proceed to
      DTC B1479/79 is not output A
      DTC B1479/79 is output B

    B
    A
  5. CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY (A/C FLOW SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Disconnect the I77 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I77-7 (FLOQ) - E75-3 (QUFL) Always Below 1 Ω
      I77-13 (SG-2) - E75-2 (SGFL) Always Below 1 Ω
      I77-30 (S5-1) - E75-1 (S5FL) Always Below 1 Ω
      I77-7 (FLOQ) - Body ground Always 10 kΩ or higher
      I77-13 (SG-2) - Body ground Always 10 kΩ or higher
      I77-30 (S5-1) - Body ground Always 10 kΩ or higher
      Result
      Result Proceed to
      OK (for TMC, TMMR Made) A
      OK (for TMMK Made) B
      NG C

    B
    C
    A
  6. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. Read the Data List according to the display on the intelligent tester.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Flow Sensor

      A/C flow sensor /

      Min.: 0 V

      Max.: 5 V

      Ignition switch ON: 0.3 to 4.7 V A/C flow sensor is malfunctioning when a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds.
      OK
      The display is as specified in the Normal Condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to Problem Symptoms Table) A
      OK (When troubleshooting according to the DTC) B
      NG (When a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds) C

    B
    C
    A
  7. READ VALUE USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body / Air Conditioner / Data List.

    5. Read the Data List according to the display on the intelligent tester.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      A/C Cutoff Signal

      A/C control cutoff signal /

      OFF or ON

      A/C switch on: OFF

      A/C switch off: ON

      -
      Result
      Result Proceed to
      Value in Data List indicates OFF A
      Value in Data List indicates ON B

    B
    A
  8. REPLACE COMPRESSOR AND MAGNET CLUTCH (A/C FLOW SENSOR)


    1. Replace the compressor and magnet clutch (A/C flow sensor) Click here.

      Tech Tips

      Since the compressor and magnet clutch (A/C flow sensor) cannot be inspected while it is removed from the vehicle, replace the compressor and magnet clutch (A/C flow sensor) with a new or a known good one and check that the condition returns to normal.

    2. Check for DTCs.

      Result
      Result Proceed to
      DTC B1479/79 is not output A
      DTC B1479/79 is output B

    B
    A
  9. CHECK HARNESS AND CONNECTOR (COMPRESSOR AND MAGNET CLUTCH (A/C FLOW SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Disconnect the I77 air conditioning amplifier assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      I77-7 (FLOQ) - E75-3 (QUFL) Always Below 1 Ω
      I77-13 (SG-2) - E75-2 (SGFL) Always Below 1 Ω
      I77-30 (S5-1) - E75-1 (S5FL) Always Below 1 Ω
      I77-7 (FLOQ) - Body ground Always 10 kΩ or higher
      I77-13 (SG-2) - Body ground Always 10 kΩ or higher
      I77-30 (S5-1) - Body ground Always 10 kΩ or higher

    NG
    OK