REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC)
Start the engine.
Check that A/C switch indicator remains on when the following conditions are met.
| *A | for LHD (for TMC, TMMR Made) | *B | for RHD |
| *C | for LHD (for TMMK Made) | - | - |
| Item | Condition |
|---|---|
| A/C Switch | On |
| A/C operation time | 15 minutes or more |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Engine coolant temperature | 45°C (113°F) or more |
*: If the ambient temperature is not within the range shown, do not perform this check.
Tech Tips
The A/C switch indicator and air conditioning system turn off if the amount of refrigerant in the system is insufficient.
Connect the intelligent tester to the DLC3.
Check for DTC B14B8 Click here.
| Result | Amount of Refrigerant | Corrective Action |
|---|---|---|
| DTC B14B8 is output | Empty or nearly empty | Check for refrigerant leaks using a halogen leak detector, and repair if necessary Click here (for TMC, TMMR Made)) Click here (for TMMK Made)). |
| DTC B14B8 is not output | Correct or insufficient | Perform a refrigerant shortage check using the intelligent tester. |
REFRIGERANT SHORTAGE CHECK USING THE INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Utility / Refrigerant Shortage Check.
According to the display on the intelligent tester, perform the refrigerant shortage check when the following conditions are met.
| Item | Condition |
|---|---|
| A/C Switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| R/F Switch | Fresh (Ambient temperature is 31°C (87°F) or more) |
| Recirculation (Ambient temperature is 30°C (86°F) or less) | |
| Blower Speed | HI |
| Temperature Setting | MAX HOT |
*: If the ambient temperature is not within the range shown, do not perform this check.
Tech Tips
Refer to the intelligent tester operator's manual for further details.
A message indicating a refrigerant shortage is displayed on the intelligent tester and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.
DTCs are not stored when performing the refrigerant shortage check using the intelligent tester.
| Result | Amount of Refrigerant | Corrective Action |
|---|---|---|
| Refrigerant shortage | Insufficient or leakage |
|
| Refrigerant correct | Correct | - |