BLIND SPOT MONITOR MAIN SWITCH INSPECTION


  1. INSPECT BLIND SPOT MONITOR MAIN SWITCH (WARNING CANCELING SWITCH ASSEMBLY)


    1. B000KDWE22
      Text in Illustration
      *a

      Component without harness connected

      (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      11 (B) - 8 (D) Blind spot monitor main switch (warning canceling switch assembly) on (not protruding) Below 1 Ω
      11 (B) - 8 (D) Blind spot monitor main switch (warning canceling switch assembly) off (protruding) 10 kΩ or higher

      If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).

    2. Check that the blind spot monitor indicator illuminates.


      1. B000KDWE23
        Text in Illustration
        *a

        Component without harness connected

        (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

        Apply battery voltage to the blind spot monitor main switch (warning canceling switch assembly) connector and check operation of the blind spot monitor indicator, as shown in the table below.

        OK
        Connection Condition Specified Condition

        Battery positive (+) → Terminal 11 (B)

        Battery negative (-) → Terminal 12 (E)

        Blind spot monitor main switch (warning canceling switch assembly) on (not protruding) Blind spot monitor indicator illuminates
        Blind spot monitor main switch (warning canceling switch assembly) off (protruding) Blind spot monitor indicator does not illuminates

        If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).

    3. Check that the switch illuminates.


      1. B000KDWE24
        Text in Illustration
        *a

        Component without harness connected

        (Blind Spot Monitor Main Switch (Warning Canceling Switch Assembly))

        Apply battery voltage to the blind spot monitor main switch (warning canceling switch assembly) and check that the switch illuminates.

        OK
        Connection Specified Condition

        Battery positive (+) → Terminal 10 (ILL+)

        Battery negative (-) → Terminal 9 (ILL-)

        Illuminates

        If the result is not as specified, replace the blind spot monitor main switch (warning canceling switch assembly).