PURGE VALVE INSPECTION


  1. INSPECT PURGE VSV


    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 23 to 26 Ω

      If the result is not as specified, replace the purge VSV.

    2. B000M5XE05
      Text in Illustration
      *a Air

      Apply battery voltage between the terminals of the purge VSV and check that the following occurs when blowing air into port E.

      OK
      Measurement Condition Specified Condition
      Battery voltage applied between terminals 1 and 2 Air flows from port F
      Battery voltage not applied between terminals 1 and 2 Air does not flow

      If the result is not as specified, replace the purge VSV.