ECM INSTALLATION


  1. INSTALL NO. 1 ECM BRACKET


    1. B000MPV

      Install the ECM bracket with the nut.

      Torque:
      12 N*m  { 122 kgf*cm, 9 ft.*lbf }
    2. B000LXC

      Connect the wire harness clamp.

    3. B000KOI

      Connect the wire harness clamp.

    4. Install the nut.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
  2. INSTALL ECM


    1. B000M9Z

      Install the ECM brackets to the ECM with the 2 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
    2. Temporarily install the screw (B).

    3. B000JBLE01

      Install the ECM with the nut.

      Torque:
      12 N*m  { 122 kgf*cm, 9 ft.*lbf }
    4. Install the screw (A).

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
    5. Tighten the screw (B).

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
    6. B000KJA

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the connectors, make sure that dirt, water or other foreign matter does not become stuck between the connectors and other part.

      • Make sure that the 2 levers are securely locked.

    7. Connect the 2 wire harness clamps.

  3. INSTALL BATTERY

    Click here

  4. INSTALL COOL AIR INTAKE DUCT SEAL (for TMC, TMMR Made)

    Click here

  5. INSTALL COOL AIR INTAKE DUCT SEAL (for TMMK Made)

  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  7. PERFORM INITIALIZATION

    Click here