2AR-FE COOLING SERVICE DATA

THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 mm (0.394 in.) or more at 95°C (203°F)
COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor (for TMC, TMMR Made) Battery voltage applied at 20°C (68°F) 5.8 to 7.4 A
Cooling fan motor (for TMMK Made) Battery voltage applied at 20°C (68°F) 7.4 to 11.4 A
No. 2 cooling fan motor (for TMC, TMMR Made) Battery voltage applied at 20°C (68°F) 5.8 to 7.4 A
No. 2 cooling fan motor (for TMMK Made) Battery voltage applied at 20°C (68°F) 7.4 to 11.4 A
RELAY
Item Tester Connection Specified Condition
Fan relay 3 - 4

Below 1 Ω

(Battery voltage not applied between terminals 1 and 2)

3 - 5

10 kΩ or higher

(Battery voltage not applied between terminals 1 and 2)

3 - 4

10 kΩ or higher

(Battery voltage is applied between terminals 1 and 2)

3 - 5

Below 1 Ω

(Battery voltage is applied between terminals 1 and 2)

RADIATOR
Item Condition Specified Condition
Radiator cap Standard value (for brand-new cap)

93.3 to 122.7 kPa (0.95 to 1.25 kgf/cm2, 13.5 to 17.8 psi)

Minimum standard value (for used cap)

78.5 kPa (0.8 kgf/cm2, 11.4 psi)