| DTC Code | DTC Name |
|---|---|
| P074011 | Torque Converter Clutch Circuit Short to Ground |
DESCRIPTION
The shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls operation of the lock-up clutch.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P074011 | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
|
|
Fail-safe function:
If the ECM detects a malfunction, it turns shift solenoid valve SL off.
MONITOR DESCRIPTION
Based on the signals from the throttle position sensor, the air flow meter and the crankshaft position sensor, the ECM sends a signal to the shift solenoid valve SL to regulate the hydraulic pressure and provide smoother torque converter clutch engagement. The shift solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short in the shift solenoid valve SL circuit, it will illuminate the MIL and store a DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Perform registration and/or initialization when parts related to the automatic transaxle are replaced Click here.
Tech Tips
After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Perform the Lock-up Function inspection in Road Test Click here.
Turn the engine switch off.
Perform step (1) again.
Check for DTCs again Click here.
PROCEDURE
CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL CIRCUIT)
Disconnect the E96 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR) Click here |
| OK |
|
REPLACE ECM Click here
CHECK HARNESS AND CONNECTOR (ECM - WIRING HARNESS CONNECTOR)
Disconnect the E8 connector from the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
| *a | Component without harness connected (Transmission Wire) |
Remove the wiring harness connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
INSPECT SHIFT SOLENOID VALVE SL Click here |
| OK |
|
REPLACE WIRING HARNESS CONNECTOR Click here
INSPECT SHIFT SOLENOID VALVE SL
| *1 | Shift Solenoid Valve SL |
Remove the shift solenoid valve SL.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE SHIFT SOLENOID VALVE SL Click here |
| OK |
|
REPLACE TRANSMISSION WIRE Click here