DESCRIPTION
The power windows operate by using the power window regulator master switch assembly or power window regulator switch assembly.
The power window regulator master switch assembly and power window regulator switch assembly connect the same power supply and ground lines.
WIRING DIAGRAM
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (POWER WINDOW MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND)
Disconnect the H11*1 or G11*2 power window regulator master switch assembly connector.
*1: for LHD
*2: for RHD
Measure the voltage and resistance according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
||||||
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
Replace the power window regulator master switch assembly.
| Result | ||
|---|---|---|
|
| NEXT |
|
CHECK POWER WINDOW CONTROL SYSTEM
Check the operation of the power windows by using the power window regulator master switch assembly and power window regulator switch assembly.
| OK |
|---|
| All power windows operate normally. |
| Result | |||
|---|---|---|---|
|
| OK |
|
END (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY WAS DEFECTIVE) |
| NG |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) for LHD: Click here |