PROCEDURE
INSPECT HEATER PUMP ASSEMBLY
| *a | Component without harness connected (Heater Pump Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Inspect heater pump assembly operation.
Connect a positive (+) lead from the battery to terminal 1 and a negative (-) lead to terminal 2, and check the pressure of the hose by hand.
Note
This inspection must be done quickly (within 10 seconds) to prevent damage to the heater pump assembly.
| OK |
|---|
| Pressure is applied to the hose. |
If the result is not as specified, replace the heater pump assembly.