AIR CONDITIONING PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL AIR CONDITIONER PRESSURE SENSOR


    1. Remove the vinyl tape from the air conditioner tube assembly and the connecting part of the air conditioner pressure sensor.

    2. Apply sufficient compressor oil to a new air conditioner pressure sensor and the connecting surface.

      Refrigerant Compressor Oil
      HFC-134a (R134a) ND-OIL 8 or equivalent
      HFO-1234yf (R1234yf) ND-OIL 12 or equivalent
    3. A01TC5TC01
      *a Turn
      *b Hold

      Using a 27 mm deep socket wrench, install the air conditioner pressure sensor.

      Torque:
      10.8 N*m  { 110 kgf*cm, 8 ft.*lbf }
    4. Connect the connector.

  2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFC-134a(R134a))

    Click here

  3. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT (for HFO-1234yf(R1234yf))

    Click here

  4. WARM UP ENGINE (for HFC-134a(R134a))

    Click here

  5. WARM UP ENGINE (for HFO-1234yf(R1234yf))

    Click here

  6. INSPECT FOR REFRIGERANT LEAK (for HFC-134a(R134a))

    Click here

  7. INSPECT FOR REFRIGERANT LEAK (for HFO-1234yf(R1234yf))

    Click here