COMPRESSOR(for 2ZR-FE) REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))

    Click here

  2. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))

    Click here

  3. REMOVE V-RIBBED BELT

    Click here

  4. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY


    1. A01TBPU

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the discharge hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  5. DISCONNECT SUCTION HOSE SUB-ASSEMBLY


    1. A01TBYQ

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  6. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY


    1. A01TAOF

      Disconnect the connector.

    2. Disengage the clamp.

    3. A01TCA9C05
      A01TCE3 Bolt
      A01TBGJ Nut

      Remove the 2 bolts and 2 nuts.

    4. A01T8X7

      Using an E8 "TORX" socket, remove the 2 stud bolts.

    5. Remove the compressor assembly with pulley.