COMPRESSOR(for 1ZR-FE, 1ZR-FAE) REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))

    Click here

  2. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))

    Click here

  3. REMOVE V-RIBBED BELT (for 1ZR-FAE)

    Click here

  4. REMOVE V-RIBBED BELT (for 1ZR-FE)

    Click here

  5. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY


    1. B0044TP

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the discharge hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  6. DISCONNECT SUCTION HOSE SUB-ASSEMBLY


    1. B004388

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  7. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY


    1. B00430L

      Disconnect the connector.

    2. Disengage the clamp.

    3. B0042TMC01
      B0042CO Bolt
      B0043VS Nut

      Remove the 2 bolts and 2 nuts.

    4. B0043X5

      Using an E8 "TORX" socket, remove the 2 stud bolts.

    5. Remove the compressor assembly with pulley.