PROCEDURE
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFC-134a(R134a))
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM (for HFO-1234yf(R1234yf))
REMOVE V-RIBBED BELT (for 1ZR-FAE)
REMOVE V-RIBBED BELT (for 1ZR-FE)
DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.
Remove the O-ring from the discharge hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
DISCONNECT SUCTION HOSE SUB-ASSEMBLY
Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.
Remove the O-ring from the suction hose sub-assembly.
Note
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
REMOVE COMPRESSOR ASSEMBLY WITH PULLEY
Disconnect the connector.
Disengage the clamp.
|
Bolt |
|
Nut |
Remove the 2 bolts and 2 nuts.
Using an E8 "TORX" socket, remove the 2 stud bolts.
Remove the compressor assembly with pulley.