PROCEDURE
INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (for Manual Air Conditioning System)
Connect the link of the No. 1 blower damper servo sub-assembly to the link of the blower assembly as shown in the illustration.
Install the No. 1 blower damper servo sub-assembly with the 2 screws.
INSTALL RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)
for LHD:
Connect the link of the recirculation damper servo sub-assembly to the link of the blower assembly as shown in the illustration.
Install the recirculation damper servo sub-assembly with the 2 screws.
for RHD:
Connect the link of the recirculation damper servo sub-assembly to the link of the blower assembly as shown in the illustration.
Install the recirculation damper servo sub-assembly with the 2 screws.
INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY (for Manual Air Conditioning System)
Install the blower motor with fan sub-assembly with the 3 screws.
INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY (for Automatic Air Conditioning System)
Install the blower motor with fan sub-assembly with the 3 screws.
INSTALL BLOWER RESISTOR (for Manual Air Conditioning System)
Install the blower resistor with the 2 screws.