COMPRESSOR(for 1WW) REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    Click here

  2. REMOVE V-RIBBED BELT

    Click here

  3. DISCONNECT SUCTION HOSE SUB-ASSEMBLY


    1. A01M24Q

      Remove the bolt and disconnect the suction hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the suction hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  4. DISCONNECT DISCHARGE HOSE SUB-ASSEMBLY


    1. A01LZIB

      Remove the bolt and disconnect the discharge hose sub-assembly from the compressor assembly with pulley.

    2. Remove the O-ring from the discharge hose sub-assembly.

      Note

      Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.

  5. REMOVE COMPRESSOR ASSEMBLY WITH PULLEY


    1. A01LYII

      Disconnect the connector.

    2. Disengage the clamp.

    3. A01LZD4C01
      A01M03W Bolt
      A01LZQW Nut

      Remove the bolt and 2 nuts.

    4. A01LZXD

      Using an E8 "TORX" socket wrench, remove the 2 stud bolts.

    5. Remove the compressor assembly with pulley.