COMBUSTION TYPE POWER HEATER SYSTEM, Diagnostic DTC:054, 056

DTC Code DTC Name
054 High Setting of Flame Cutout
056 Low Setting of Flame Cutout

DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area
054 High Setting of Flame Cutout Combustion ends abnormally. (High output operation)
  • No. 2 exhaust pipe sub-assembly

  • Intake air duct

  • Fuel pump filter

  • Heater pump assembly

  • Heater assembly

056 Low Setting of Flame Cutout Combustion ends abnormally. (Low output operation)
  • No. 2 exhaust pipe sub-assembly

  • Intake air duct

  • Fuel pump filter

  • Heater pump assembly

  • Heater assembly

CAUTION / NOTICE / HINT

Tech Tips

Before performing the following inspection procedure, attempt to restart the heater assembly. If the heater assembly is successfully started, confirm that neither DTC 054 nor DTC 056 is output. If neither DTC 054 nor 056 is output, finish troubleshooting because it can be determined that the system has returned to normal operation.

PROCEDURE


  1. INSPECT INTAKE AIR DUCT


    1. Inspect the intake air duct.

      Result
      Result Proceed to
      There is no problem with the intake air duct. A
      The intake air duct is clogged, or other problems are found. B

    B
    A
  2. INSPECT NO. 2 EXHAUST PIPE SUB-ASSEMBLY


    1. Inspect the No. 2 exhaust pipe sub-assembly.

      Result
      Result Proceed to
      There is no problem with the No. 2 exhaust pipe sub-assembly. A
      The No. 2 exhaust pipe sub-assembly is clogged, or other problems are found. B

    B
    A
  3. INSPECT HEATER PUMP ASSEMBLY


    1. Disconnect the A99 heater pump assembly connector.

    2. A012GSXC01
      *a

      Component without harness connected

      (Heater Pump Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 9 to 12 Ω
    3. Inspect heater pump assembly operation.


      1. Connect a positive (+) lead from the battery to terminal 1 and a negative (-) lead to terminal 2, and check the pressure of the hose by hand.

        Note

        This inspection must be done quickly (within 10 seconds) to prevent damage to the heater pump assembly.

        OK
        Pressure is applied to the hose.
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. REPLACE FUEL FILTER ASSEMBLY


    1. Replace the fuel filter assembly with a new one and check that the condition returns to normal.

      for 1AD-FTV: Click here

      for 1ND-TV: Click here

      OK
      The heater is ignites normally and starts operating.
      Result
      Proceed to
      OK
      NG

    OK
    NG