| DTC Code | DTC Name |
|---|---|
| B1451/51 | Compressor Solenoid Circuit |
DESCRIPTION
In this circuit, the compressor assembly with pulley (compressor solenoid) receives a refrigerant compression demand signal from the air conditioning amplifier assembly.
Based on this signal, the compressor assembly with pulley (compressor solenoid) changes the amount of compressor output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1451/51 | Compressor Solenoid Circuit | Open or short in compressor solenoid circuit |
|
- |
WIRING DIAGRAM
| *a | Compressor Assembly with Pulley (Compressor Solenoid) |
| *b | Air Conditioning Amplifier Assembly |
PROCEDURE
INSPECT COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID)
Disconnect the B7 compressor assembly with pulley (compressor solenoid) connector.
| *a | Component without harness connected (Compressor Assembly with Pulley (Compressor Solenoid)) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPLACE COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID) for 1AD-FTV: Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID) - BODY GROUND)
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| Result | |||
|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (COMPRESSOR ASSEMBLY WITH PULLEY (COMPRESSOR SOLENOID) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Disconnect the E28 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| A |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |