DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Cooler (room temp. sensor) thermistor | Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | *1 |
| Ambient Temp Sensor | Thermistor assembly | Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor | Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | *1 |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | *1 |
| Solar Sensor (D Side) | Driver side cooler (solar sensor) thermistor*2 or cooler (solar sensor) thermistor*3 | Min.: 0 Max.: 255 |
Driver side cooler (solar sensor) thermistor*2 or cooler (solar sensor) thermistor*3 value increases as brightness increases | *1 |
| Solar Sensor (P Side) | Front passenger side cooler (solar sensor) thermistor | Min.: 0 Max.: 255 |
Front passenger side cooler (solar sensor) thermistor value increases as brightness increases | *1, *2 |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Driver side set temperature*2 or set temperature*3 | Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature*2 or set temperature*3 displayed | *1 |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed | *1, *2 |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG Max.: 3.2943 MPaG |
Actual pressure displayed | *1 |
| Regulator Control Current | Solenoid valve control current | Min.: 0 A Max.: 0.997 A |
Value changes between 0 A and 0.997 A in accordance with solenoid valve operation | *1 |
| Air Mix Servo Targ Pulse(D) | Air mix damper servo sub-assembly (for driver side)*2 or air mix damper servo sub-assembly*3 target pulse | Min.: 0 Max.: 255 |
for LHD:
for RHD: |
- |
| Air Mix Servo Actual Pulse(D) | Air mix damper servo sub-assembly (for driver side)*2 or air mix damper servo sub-assembly*3 actual pulse | Min.: 0 Max.: 255 |
for LHD:
for RHD: |
- |
| Air Mix Servo Targ Pulse(P) | Air mix damper servo sub-assembly (for front passenger side) target pulse | Min.: 0 Max.: 255 |
for LHD:
for RHD: |
*1, *2 |
| Air Mix Servo Actual Pulse(P) | Air mix damper servo sub-assembly (for front passenger side) actual pulse | Min.: 0 Max.: 255 |
for LHD:
for RHD: |
*1, *2 |
| Air Outlet Servo Pulse (D) | Mode damper servo sub-assembly target pulse | Min.: 0 Max.: 255 |
FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 18 (pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) |
- |
| Air Outlet Servo Actu Pulse(D) | Mode damper servo sub-assembly actual pulse | Min.: 0 Max.: 255 |
FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 18 (pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) |
- |
| Air Inlet Damper Targ Pulse | Recirculation damper servo sub-assembly target pulse | Min.: 0 Max.: 255 |
for LHD:
for RHD: |
- |
| Air Inlet Damper Actual Pulse | Recirculation damper servo sub-assembly actual pulse | Min.: 0 Max.: 255 |
for LHD:
for RHD: |
- |
| Electric Heater Count | Maximum electric heater operation level | Min.: 0 Max.: 3 |
Maximum possible operation of electric heater displayed | *4 |
| Electric Heater Active Level | Actual electric heater operation level | Min.: 0 Max.: 3 |
Actual operation level of electric heater displayed | *4 |
| Shift Set Temperature | Shift set temperature | 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | *1 |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | *1 |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | *1 |
| Evaporator Control | Evaporator control | Auto or Manual | Customized value displayed | *1 |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | *1 |
| Fan speed increment control | Fan speed increment control | Slow, Normal, Fast | Customized value displayed | *1 |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | *1 |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | *1 |
| A/C Cutoff Signal | A/C control cutoff signal | OFF or ON | The ECM sends the air conditioning control cutoff signal displayed | *1 |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | *1 |
| Blower Operation Setting (Stop&Start) | Blower operation setting (stop&start) | Blower OFF or Blower Level 1 | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes | Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
*1: w/ Cooler System
*2: for Dual Type
*3: for Single Type
*4: w/ PTC Heater
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Magnetic Clutch Relay | A/C system operation | OFF, ON | *1 |
| Defogger Relay (Rear) | Defogger relay | OFF, ON | - |
| Heater Active Level | Quick heater assembly | Min.: 0, Max.: 3 | *4 |
| Air Mix Servo Targ Pulse(D) | Air mix damper servo sub-assembly (for driver side)*2 or air mix damper servo sub-assembly*3 pulse | Min.: 0, Max.: 255 |
for LHD
for RHD |
| Air Mix Servo Targ Pulse(P) | Air mix damper servo sub-assembly (for front passenger side) pulse*1, *2 | Min.: 0, Max.: 255 |
for LHD
for RHD |
| Air Outlet Servo Pulse (D) | Mode damper servo sub-assembly pulse | Min.: 0, Max.: 255 | Operates between 5 and 47 pulses |
| Air Inlet Damper Targ Pulse | Recirculation damper servo sub-assembly pulse | Min.: 0, Max.: 255 |
for LHD
for RHD |
*1: w/ Cooler System
*2: for Dual Type
*3: for Single Type
*4: w/ PTC Heater