AUDIO AND VISUAL SYSTEM(except Sedan Radio and Display Type) AVC-LAN Circuit

DESCRIPTION

Each unit of the audio and visual system connected to the AVC-LAN (communication bus) transfers switch signals using the AVC-LAN.

If a short to +B or short to ground occurs in the AVC-LAN, the audio and visual system will not function normally because communication is not possible.

WIRING DIAGRAM

A01KRDKE30
*1 Stereo Component Amplifier Assembly
*2 Radio and Display Receiver Assembly

CAUTION / NOTICE / HINT

Tech Tips

The radio and display receiver assembly is the master unit.

PROCEDURE


  1. INSPECT RADIO AND DISPLAY RECEIVER ASSEMBLY


    1. Remove the radio and display receiver assembly.

    2. A01KTUKC04
      *a

      Component without harness connected

      (Radio and Display Receiver Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      7 (TX1+) - 8 (TX1-) Always 60 to 80 Ω
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (AVC-LAN CIRCUIT)


    1. Disconnect the E60 radio and display receiver assembly connector.

    2. Disconnect the E92 stereo component amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      E92-8 (TX+) - E60-7 (TX1+) Always Below 1 Ω
      E92-7 (TX-) - E60-8 (TX1-) Always Below 1 Ω
      E92-8 (TX+) - Body ground Always 10 kΩ or higher
      E92-7 (TX-) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. INSPECT MALFUNCTIONING PARTS


    1. Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.

      Tech Tips


      • Check all slave units.

      • If disconnecting a slave unit causes the master unit to return to normal operation, the slave unit is defective and should be replaced.

      OK
      Master unit returns to normal operation.
      Result
      Proceed to
      OK
      NG

    OK
    NG