PATTERN SELECT SWITCH(for TMMT Made) INSPECTION

PROCEDURE


  1. INSPECT PATTERN SELECT SWITCH ASSEMBLY


    1. A00Y5G8C01
      *a

      Component without harness connected

      (Pattern Select Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      5 (MSW1) - 2 (MSW2) Pressed Below 1 Ω
      Not pressed 10 kΩ or higher

      If the result is not as specified, replace the pattern select switch assembly.

    2. A00Y5G8C02
      *a

      Component without harness connected

      (Pattern Select Switch Assembly)

      Apply battery voltage between the terminals of the switch and check the illumination condition of the pattern select switch assembly.

      Standard
      Measurement Condition Specified Condition

      Battery positive (+) → 4 (MSW+)

      Battery negative (-) → 3 (MSW-)

      Illuminates

      If the result is not as specified, replace the pattern select switch assembly.