CONTINUOUSLY VARIABLE TRANSAXLE SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

The ECM uses signals to control shift solenoid valve SLT to provide optimum line pressure control. Shift solenoid valve SLT is also used during forward and reverse clutch engagement to control the oil pressure to the forward and reverse clutch.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
  1. Diagnosis Condition


    • The vehicle is being driven.

  2. Malfunction Status


    • There is an open or short circuit in the shift solenoid valve SLT circuit.

  3. Malfunction Time


    • 1 second or more

  4. Other


    • 1-trip detection logic


  • Wire harness or connector

  • Continuously variable transaxle assembly (Shift solenoid valve SLT)

  • ECM

Comes on DTC stored

MONITOR DESCRIPTION

This DTC indicates an open or short circuit in the shift solenoid valve SLT circuit. When there is an open or short circuit in the shift solenoid valve SLT circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.

WIRING DIAGRAM

A01T8V9E83
*a Shift Solenoid Valve SLT
*b Continuously Variable Transaxle Assembly (Transmission Wire)

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)


    1. A01T9G9C32
      *a

      Component without harness connected

      (Transmission Wire)

      Disconnect the B90 transmission wire connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (SLT+) - 7 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      2 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      7 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
    3. Connect the B90 transmission wire connector.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. Disconnect the B186 ECM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      B186-39 (SLT+) - B186-38 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
      B186-39 (SLT+) - Body ground and other terminals Always 10 kΩ or higher
      B186-38 (SLT-) - Body ground and other terminals Always 10 kΩ or higher
    3. Connect the B186 ECM connector.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. REPLACE ECM


    1. Replace the ECM.

      for 1ZR-FE: Click here

      for 2ZR-FE: Click here

      Result
      Proceed to
      NEXT

    NEXT
  4. REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY


    1. Replace the continuously variable transaxle assembly.

      Click here

      Result
      Proceed to
      NEXT

    NEXT