PARK / NEUTRAL POSITION SWITCH INSTALLATION

PROCEDURE


  1. INSTALL NEUTRAL POSITION SWITCH


    1. A00Y4X2N01

      Using SST, install a new gasket and the neutral position switch to the manual transmission case.

      SST
      09816-30010
      Torque:
      40.2 N*m  { 410 kgf*cm, 30 ft.*lbf }
    2. Connect the neutral position switch connector.