MULTI-MODE MANUAL TRANSAXLE SYSTEM, Diagnostic DTC:P0915, P0916, P0917

DTC Code DTC Name
P0915 Gear Shift Position Circuit Range / Performance
P0916 Gear Shift Position Circuit Low
P0917 Gear Shift Position Circuit High

DESCRIPTION

The shift stroke sensor is mounted on the shift and select actuator, and detects the shift position of the shift and select lever shaft. The sensor consists of a sensor arm, magnetic yoke and 2 Hall ICs. This sensor is a non-contact type, and uses Hall-effect elements (Hall ICs: main and sub), in order to yield accurate signals.

When the shift and select actuator is operating in the shift direction, the magnetic yoke that is coaxially positioned on the sensor arm is rotated and the magnet position changes. The Hall ICs convert the magnet position change into the voltage signal and send it to the TCM. The TCM judges the shift motor operating condition (which gear is selected: reverse, 1st, 3rd and 5th or 2nd, 4th and 6th) based on the signal from the shift stroke sensor.

A01TB7UC02
*a Shift and Select Actuator Operation
*b Shift Direction
*c Select Direction

The main and sub circuits in the shift stroke sensor have the same output characteristics.

The sensor construction and operation of the shift stroke sensor are basically the same as those of the clutch stroke sensor.

A01T9UOE13
DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Memory
P0915 Gear Shift Position Circuit Range / Performance

Deviation between sensor signal 1 (main) and sensor signal 2 (sub) is 2.0 mm (0.078 in.) or more for 1.0second or more

(1-trip detection logic)


  • Shift stroke sensor

  • Open or short in shift stroke sensor circuit

  • TCM

Does not come on Comes on DTC stored
P0916 Gear Shift Position Circuit Low
  • Shift stroke sensor (main) signal voltage is 0.2 V or less for 0.5 seconds or more

    (1-trip detection logic)

  • Shift stroke sensor (sub) signal voltage is 0.2 V or less for 0.5 seconds or more

    (1-trip detection logic)


  • Shift stroke sensor

  • Open or short in shift stroke sensor circuit

  • TCM

Comes on Comes on DTC stored
P0917 Gear Shift Position Circuit High
  • Shift stroke sensor (main) signal voltage is 4.8 V or more for 0.5 seconds or more

    (1-trip detection logic)

  • Shift stroke sensor (sub) signal voltage is 4.8 V or more for 0.5 seconds or more

    (1-trip detection logic)


  • Shift stroke sensor

  • Open or short in shift stroke sensor circuit

  • TCM

Comes on Comes on DTC stored

WIRING DIAGRAM

A01TAS8E01
*a Sub
*b Main
*c Shift Stroke Sensor

CAUTION / NOTICE / HINT

Note

When installing parts related to the multi-mode manual transaxle system, perform the initialization and learning and synchronization position calibration procedures. In addition, the required operations differ according to the parts to be installed. Proceed with the operation in the order shown in the table below.

After Installation
Part Installed Part Installed See Procedure

  • Transaxle assembly

  • Transaxle parts (inside gear box)

  • TCM

  • Clutch actuator assembly

  • Clutch disc and clutch cover

  • Clutch release with bearing cylinder assembly

  • Flywheel

  • Crankshaft

1. Initialization of multi-mode manual transaxle system

[Tester display: Initialization of ECU]

Click here

2. Learning of multi-mode manual transaxle system
3. Synchronization position calibration

  • Shift and select actuator

  • Shift stroke sensor

  • Select stroke sensor

1. Initialization of multi-mode manual transaxle system

[Tester display: Initialization of transmission]

2. Learning of multi-mode manual transaxle system
3. Synchronization position calibration

  • Clutch stroke sensor

1. Initialization of multi-mode manual transaxle system

[Tester display: Initialization of clutch]

2. Learning of multi-mode manual transaxle system

If the sensor or actuator is installed without the initialization and learning procedures, it may cause driving performance degradation or system component breakage.

PROCEDURE


  1. INSPECT TCM (VCS1 AND VCS2 VOLTAGE)


    1. Disconnect the shift stroke sensor connector.

    2. A01TBF5C07
      *a

      Front view of wire harness connector

      (to Shift Stroke Sensor)

      Turn the ignition switch to ON.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A107-2 (E2S1) - A107-3 (VCS1) Ignition switch ON 4.7 to 5.3 V
      A107-5 (E2S2) - A107-6 (VCS2) Ignition switch ON 4.7 to 5.3 V
      Result
      Proceed to
      OK
      NG

    NG
    OK
  2. INSPECT SHIFT STROKE SENSOR


    1. Remove the shift stroke sensor.

    2. A01TAWQC03
      *1 Sensor Arm
      *a

      Component without harness connected

      (Shift Stroke Sensor)

      *b Main

      Measure the voltage between the terminals of the shift stroke sensor connector (main).


      1. Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.

      2. Connect the batteries in series.

      3. Connect the positive battery terminal to sensor terminal 3 (VCS1), and the negative battery terminal to sensor terminal 2 (E2S1).

      4. Measure the voltage according to the value(s) in the table below.

        Standard Voltage (combined dry cell battery voltage of 4.5 V)
        Tester Connection Condition(Sensor Angle) Specified Condition
        1 (VSS1) - 2 (E2S1) 55° 3.6 to 4.5 V
        1.8 to 2.7 V
        -55° 0.27 to 0.63 V
        Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)
        Tester Connection Condition(Sensor Angle) Specified Condition
        1 (VSS1) - 2 (E2S1) 55° 4.0 to 5.0 V
        2.0 to 3.0 V
        -55° 0.3 to 0.7 V
    3. A01TAWQC04
      *1 Sensor Arm
      *a

      Component without harness connected

      (Shift Stroke Sensor)

      *b Sub

      Measure the voltage between the terminals of the shift stroke sensor connector (sub).


      1. Connect the positive battery terminal to sensor terminal 6 (VCS2), and the negative battery terminal to sensor terminal 5 (E2S2).

      2. Measure the voltage according to the value(s) in the table below.

        Standard Voltage (combined dry cell battery voltage of 4.5 V)
        Tester Connection Condition(Sensor Angle) Specified Condition
        4 (VSS2) - 5 (E2S2) 55° 3.6 to 4.5 V
        1.8 to 2.7 V
        -55° 0.27 to 0.63 V
        Reference Voltage (combined dry cell battery voltage of 5.0 +/- 0.3 V)
        Tester Connection Condition(Sensor Angle) Specified Condition
        4 (VSS2) - 5 (E2S2) 55° 4.0 to 5.0 V
        2.0 to 3.0 V
        -55° 0.3 to 0.7 V

        Note


        • Do not apply more than 6 V.

        • Do not use a sensor which has been dropped.

      Result
      Proceed to
      OK
      NG

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (SHIFT STROKE SENSOR - TCM)


    1. Disconnect the TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A107-1 (VSS1) - A108-18 (VSS1) Always Below 1 Ω
      A107-4 (VSS2) - A108-29 (VSS2) Always Below 1 Ω
      A108-18 (VSS1) - Body ground Always 10 kΩ or higher
      A108-29 (VSS2) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  4. REPLACE TCM


    1. Replace the TCM.

      for LHD: Click here

      for RHD: Click here

      Result
      Proceed to
      NEXT

    NEXT
  5. PERFORM INITIALIZATION


    1. Perform the initialization and learning procedure.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  6. REPLACE SHIFT STROKE SENSOR


    1. Replace the shift stroke sensor.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  7. PERFORM INITIALIZATION


    1. Perform the initialization and learning procedure.

      Click here

      Result
      Proceed to
      NEXT

    NEXT
  8. CHECK HARNESS AND CONNECTOR (SHIFT STROKE SENSOR - TCM)


    1. Disconnect the TCM connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A107-2 (E2S1) - A108-17 (E2S1) Always Below 1 Ω
      A107-3 (VCS1) - A108-19 (VCS1) Always Below 1 Ω
      A107-5 (E2S2) - A108-28 (E2S2) Always Below 1 Ω
      A107-6 (VCS2) - A108-30 (VCS2) Always Below 1 Ω
      A108-17 (E2S1) - Body ground Always 10 kΩ or higher
      A108-19 (VCS1) - Body ground Always 10 kΩ or higher
      A108-28 (E2S2) - Body ground Always 10 kΩ or higher
      A108-30 (VCS2) - Body ground Always 10 kΩ or higher
      Result
      Proceed to
      OK
      NG

    NG
    OK
  9. REPLACE TCM


    1. Replace the TCM.

      for LHD: Click here

      for RHD: Click here

      Result
      Proceed to
      NEXT

    NEXT
  10. PERFORM INITIALIZATION


    1. Perform the initialization and learning procedure.

      Click here

      Result
      Proceed to
      NEXT

    NEXT