PROCEDURE
INSPECT CLUTCH STROKE SENSOR
| *a | Main Circuit |
| *b | Sensor Arm |
| *c | 55° |
| *d | 0° |
| *e | -55° |
Check the voltage between the terminals of the clutch stroke sensor connector (main circuit).
Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.
Connect the batteries in series.
Connect a positive (+) lead from the battery to sensor terminal 3, and a negative (-) lead to sensor terminal 2.
Measure the voltage according to the values in the table below.
| Standard Voltage (combined dry cell battery voltage of 4.5 V) | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| Reference Voltage (5.0 +/- 0.3 V) | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply more than 6 V.
Do not use a sensor which has been dropped.
If the voltage is not as specified, replace the clutch stroke sensor.
| *a | Sub Circuit |
| *b | Sensor Arm |
| *c | 55° |
| *d | 0° |
| *e | -55° |
Check the voltage between the terminals of the clutch stroke sensor connector (sub circuit).
Prepare 3 dry cell batteries (1.5 V) and 2 leads for connecting the batteries and the sensor.
Connect the batteries in series.
Connect a positive (+) lead from the battery to sensor terminal 6, and a negative (-) lead to sensor terminal 5.
Measure the voltage according to the values in the table below.
| Standard Voltage (combined dry cell battery voltage of 4.5 V) | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| Reference Voltage (5.0 +/- 0.3 V) | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Note
Do not apply more than 6 V.
Do not use a sensor which has been dropped.
If the voltage is not as specified, replace the clutch stroke sensor.