STOP AND START SYSTEM Stop and Start System does not Operate (Battery Condition)

DESCRIPTION

When the stop and start system does not operate, check whether the operation is prohibited because the battery conditions are not met.

Tech Tips

Data List items:


  • Oper Permission (Battery)

  • Oper Permission (Start Min Volt 1)

  • Oper Permission (Start Min Volt 2)

  • Oper Permission (Start Min Volt 3)

  • Oper Permission (Start Min Volt 4)

  • Oper Permission (Battery Current)

  • Oper Permission (Integrated Current)

  • Oper Prohibition (Jump Start)

  • Oper Prohibition (Manual Start)

PROCEDURE


  1. CHECK DTC OUTPUT


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Stop and Start / Trouble Codes.

    5. Read the DTCs.


      Powertrain > Stop and Start > Trouble Codes
      Result
      Result Proceed to
      DTC is not output A
      DTC is output B

    B
    A
  2. READ VALUE USING GTS


    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG/OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -
      Oper Permission (Start Min Volt 1) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or lower and the minimum voltage at starter ON is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 2) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 3) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or lower and the minimum voltage right after engine cranking is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 4) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Battery Current) Permission of stop and start control based on the battery conditions NG/OK OK: Battery discharge current is -125 A or less Engine stop and start ECU calculated value
      Oper Permission (Integrated Current) Permission of stop and start control based on the integrated current value conditions NG/OK OK: Integrated current value more than specified The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.
      Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start conditions Permit/Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned to START When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.
      Oper Prohibition (Manual Start) Prohibition of stop and start control based on the manual start conditions Permit/Prohibit Prohibit: During manual start

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

      Conditions for Manual Start:


      • Clutch start switch OFF or vehicle speed signal input

      • Neutral position switch OFF

      • Starter signal OFF


      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery)
      Oper Permission (Start Min Volt 1)
      Oper Permission (Start Min Volt 2)
      Oper Permission (Start Min Volt 3)
      Oper Permission (Start Min Volt 4)
      Oper Permission (Battery Current)
      Oper Permission (Integrated Current)
      Oper Prohibition (Jump Start)
      Oper Prohibition (Manual Start)
      Result
      Proceed to
      NEXT

    NEXT
  3. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tech Tips

    Check whether stop and start control was prohibited based on the battery conditions or other conditions.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Type Range Diagnostic Note
      Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG/OK OK: Stop and start control is permitted due to battery condition, or Active Test (forced permission) is performed -

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery)
      Result
      Result Proceed to
      NG is displayed A
      OK is displayed B

    B
    A
  4. READ VALUE USING GTS (STATUS OF BATTERY CHARGE CONTROL)

    Tech Tips

    Check whether stop and start control was prohibited based on the battery charge control mode.


    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Status of Battery Charge Control.

    3. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Status of Battery Charge Control Battery charge control status Change Control Condition Mode/Stop and Start Standalone/Refresh Charge Mode/Stop and Start Restriction Mode/Temperature High/Low Mode/Abnormal Mode/Battery Condition Judgment Mode/Low Temperature Mode - -

      Powertrain > Stop and Start > Data List
      Tester Display
      Status of Battery Charge Control
      Result
      Result Proceed to
      "Refresh Charge Mode", "Battery Condition Judgment Mode" or "Abnormal Mode" is not displayed A
      "Refresh Charge Mode" is displayed B
      "Battery Condition Judgment Mode" is displayed C
      "Abnormal Mode" is displayed (for 1AD-FTV) D
      "Abnormal Mode" is displayed (for 1ND-TV) E
      "Abnormal Mode" is displayed (for 1NR-FE) F

      Tech Tips

      If "Refresh Charge Mode" is displayed, leave the vehicle idling for 30 to 60 minutes.


    B
    C
    D
    E
    F
    A
  5. READ VALUE USING GTS (OPER PERMISSION (START MIN VOLT 1, 2, 3, 4))

    Tech Tips

    Check whether stop and start control was prohibited based on the minimum starting voltage of the battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Start Min Volt 1) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or lower and the minimum voltage at starter ON is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 2) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage at starter ON is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 3) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or lower and the minimum voltage right after engine cranking is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted
      Oper Permission (Start Min Volt 4) Permission of stop and start control based on the battery conditions NG/OK OK: Battery temperature is 0°C (32°F) or higher and the minimum voltage right after engine cranking is the threshold value or higher If 2 or more of Start Min Volt 1, 2, 3, or 4 are OK, stop and start control is permitted

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Start Min Volt 1)
      Oper Permission (Start Min Volt 2)
      Oper Permission (Start Min Volt 3)
      Oper Permission (Start Min Volt 4)
      Result
      Result Proceed to
      OK is displayed for 2 or more items A
      OK is displayed for 1 item or none B

      1. The Data List item "Oper Permission (Start Min Volt 1, 2, 3, 4)" is judged OK or NG according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Battery Temp (Start) Battery temperature at engine start Min.: -40°C (-40°F), Max.: 100°C (212°F) Same as temperature around battery at engine start (after engine start) -
        Ambient Temp Sensor Ambient temperature Min.: -30°C (-22°F), Max.: 50°C (122°F) Close to ambient temperature -
        Min Voltage(Cranking) Minimum battery voltage while engine cranking (incurrent trip) Min.: 0 V ,Max.: 327.67 V 6 to 11 V Lowest battery voltage measured in a 5 second period after the starter starts operating.
        Min Volt(After Cranking) Minimum battery voltage just after engine cranking Min.: 0 V ,Max.: 327.67 V 6 to 11 V Minimum battery voltage while starter driving

        Powertrain > Stop and Start > Data List
        Tester Display
        Battery Temp (Start)
        Ambient Temp Sensor
        Min Voltage(Cranking)
        Min Volt(After Cranking)
        Permission Criteria
        Tester Display Starting Battery Voltage Battery Temperature*1
        Oper Permission (Start Min Volt 1)*2 8.14 V or higher 0°C (32°F) or lower
        Oper Permission (Start Min Volt 2)*2 8.14 V or higher Higher than 0°C (32°F)
        Oper Permission (Start Min Volt 3)*3 8.14 V or higher 0°C (32°F) or lower
        Oper Permission (Start Min Volt 4)*3 8.14 V or higher Higher than 0°C (32°F)

        • *1: Read the Data List items "Battery Temp (Start)" and "Ambient Temp Sensor" when checking the battery temperature.

        • *2: Operation is permitted when the minimum voltage is 8.14 V or more when 0.0049 seconds have elapsed after cranking the engine.

        • *3: Operation is permitted when the minimum voltage is 8.14 V or more right after cranking the engine.


    B
    A
  6. READ VALUE USING GTS (OPER PERMISSION (BATTERY CURRENT))

    Tech Tips

    Check whether the stop and start control was prohibited based on the battery discharge current battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery Current).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Battery Current) Permission of stop and start control based on the battery conditions NG/OK OK: Battery discharge current is -125 A or less Engine stop and start ECU calculated value

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery Current)
      Result
      Result Proceed to
      OK is displayed A
      NG is displayed B

      1. The Data List item "Oper Permission (Battery Current)" is judged OK or NG according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Battery Current Battery current Min.: 0 A, Max.: 124.99 A - -

        Powertrain > Stop and Start > Data List
        Tester Display
        Battery Current
        Permission Criteria
        Tester Display Battery Current
        Oper Permission (Battery Current) -125 A or less

    B
    A
  7. READ VALUE USING GTS (OPER PERMISSION (INTEGRATED CURRENT))

    Tech Tips

    Check whether the stop and start control was prohibited based on the integrated current value battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Integrated Current).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Integrated Current) Permission of stop and start control based on the integrated current value conditions NG/OK OK: Integrated current value more than specified

      The condition is judged based on the integrated current value.

      The status depend on the value of "Integrated Current", and OK/NG threshold differs according to the battery temperature.


      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Integrated Current)
      Result
      Result Proceed to
      OK is displayed A
      NG is displayed B

    B
    A
  8. READ VALUE USING GTS (STATE OF BBC AND BBC CHECK RESULT)

    Tech Tips

    Check the operation of the backup boost converter.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / State of BBC and BBC Check Result.

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      State of BBC Backup boost converter status Cycle Err / Overvol / Overload / Normal / Low Vol / Duty Err / S&S Sensor Electric Supply Low / S&S CPU Malfunction / BBC Overcurrent / S&S Starter Overcurrent / S&S Reduced Voltage Reset status Normal: Backup boost converter operating normally
      • Cycle Err:


        • Abnormal output voltage cycle is detected

      • Overvol:


        • When the ignition switch is ON:


          1. Overvoltage is detected at the control IC power source within the backup boost converter

          2. Overheating is detected at the control IC power source within the backup boost converter


        • When boosting:


          1. Error is detected in the feedback circuit in the backup boost converter

          2. Too high or low output voltage

      • Overload:


        • Overcurrent is detected.

      • Low Vol:


        • A decrease in the voltage of the control IC power source within the backup boost converter is detected when ignition switch is turned to ON.

      • Duty Err:


        • Abnormal duty ratio is detected

      BBC Check Result Backup boost converter check result Normal / Abnormal - -

      Powertrain > Stop and Start > Data List
      Tester Display
      State of BBC
      BBC Check Result
      Result
      Result Proceed to
      Normal is displayed A
      Normal is not displayed B

    B
    A
  9. READ VALUE USING GTS (OPER PROHIBITION (JUMP START))

    Tech Tips

    Check whether stop and start control was prohibited based on the jump start battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Jump Start).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Prohibition (Jump Start) Prohibition of stop and start control based on the jump start conditions Permit / Prohibit Prohibit: Engine started with the engine hood open and the ignition switch turned to START When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Prohibition (Jump Start)
      Result
      Result Proceed to
      Permit is displayed A
      Prohibit is displayed B

      1. The Data List item "Oper Permission (Jump Start)" is judged Permit or Prohibit according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Hood Courtesy Switch Hood courtesy switch signal ON / OFF

        ON: Engine hood closed

        OFF: Engine hood open

        -
        Oper Permission (Engine Hood Closed) Permission of stop and start control based on the engine hood open/close conditions NG / OK OK: Engine hood closed -

        Powertrain > Stop and Start > Data List
        Tester Display
        Hood Courtesy Switch
        Oper Permission (Engine Hood Closed)
        Permission Criteria
        Tester Display Conditions
        Oper Prohibition (Jump Start) ON (Engine hood closed) is displayed for Hood Courtesy Switch
        OK (Engine Hood Closed) is displayed for Oper Permission (Engine Hood Closed)

    B
    A
  10. READ VALUE USING GTS (OPER PROHIBITION (MANUAL START))

    Tech Tips

    Check whether the stop and start control was prohibited based on the manual start battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Prohibition (Manual Start).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Prohibition (Manual Start) Prohibition of stop and start control based on the manual start conditions Permit / Prohibit Prohibit: During manual start

      When Prohibit is displayed, the stop and start control will be prohibited until the ignition switch is turned off.

      Conditions for Manual Start:


      • Clutch start switch OFF or vehicle speed signal input

      • Neutral position switch OFF

      • Starter signal OFF


      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Prohibition (Manual Start)
      Result
      Result Proceed to
      Permit is displayed A
      Prohibit is displayed B

      Tech Tips

      If Prohibit is displayed, start the engine using a key.


    B
    A
  11. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tech Tips

    Check whether the stop and start control was prohibited based on the battery temperature battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery)
      Result
      Result Proceed to
      NG is displayed A
      OK is displayed B

      1. The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Battery Temp (Start) Battery temperature at engine start Min.: -40°C (-40°F), Max.: 100°C (212°F) Same as temperature around battery at engine start (after engine start) -
        Ambient Temp Sensor Ambient temperature Min.: -30°C (-22°F), Max.: 50°C (122°F) Close to ambient temperature -

        Powertrain > Stop and Start > Data List
        Tester Display
        Battery Temp (Start)
        Ambient Temp Sensor
        Permission Criteria
        Tester Display Battery Temperature*
        Oper Permission (Battery) Current battery temperature is between -10°C (14°F) and 70°C (158°F)

        Tech Tips

        *: Read the Data List items "Battery Temp (Start)" and "Ambient Temp Sensor" when checking the battery temperature.


    B
    A
  12. READ VALUE USING GTS (BATTERY TEMP (START))

    Tech Tips

    Check the battery temperature.


    1. Enter the following menus: Powertrain / Stop and Start / Data List.

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Battery Temp (Start) Battery temperature at engine start Min.: -40°C (-40°F), Max.: 100°C (212°F) Same as temperature around battery at engine start (after engine start) -
      Ambient Temp Sensor Ambient temperature Min.: -30°C (-22°F), Max.: 50°C (122°F) Close to ambient temperature -

      Powertrain > Stop and Start > Data List
      Tester Display
      Battery Temp (Start)
      Ambient Temp Sensor
      Result
      Result Proceed to
      Battery temperature is as specified A
      Battery temperature is not as specified B

      Tech Tips

      If the battery temperature is not as specified, leave the battery under room temperature conditions until its temperature becomes as specified.


    B
    A
  13. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tech Tips

    Check whether stop and start control was prohibited based on the alternator status battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery)
      Result
      Result Proceed to
      NG is displayed A
      OK is displayed B

      1. The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Alternator Status Alternator power generation status Normal / Abnormal Normal: Alternator operation normal -

        Powertrain > Stop and Start > Data List
        Tester Display
        Alternator Status
        Permission Criteria
        Tester Display Conditions
        Oper Permission (Battery) Normal is displayed for Alternator Status (Alternator is generating power)
        Charge indicator lamp is off when the engine is running (Alternator is generating power)

    B
    A
  14. READ VALUE USING GTS (ALTERNATOR STATUS)

    Tech Tips

    Check the power generation status of the alternator.


    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Alternator Status.

    3. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Alternator Status Alternator power generation status Normal / Abnormal Normal: Alternator operation normal -

      Powertrain > Stop and Start > Data List
      Tester Display
      Alternator Status
      Result
      Result Proceed to
      Normal is displayed A
      Abnormal is displayed (for 1AD-FTV) B
      Abnormal is displayed (for 1ND-TV) C
      Abnormal is displayed (for 1NR-FE) D

    B
    C
    D
    A
  15. READ VALUE USING GTS (OPER PERMISSION (BATTERY))

    Tech Tips

    Check whether stop and start control was prohibited based on the idling stop rate battery condition.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Oper Permission (Battery).

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Oper Permission (Battery) Permission of stop and start control based on the battery conditions NG / OK OK: Stop and start control is permitted based on battery conditions, or Active Test (forced permission) is performed -

      Powertrain > Stop and Start > Data List
      Tester Display
      Oper Permission (Battery)
      Result
      Result Proceed to
      NG is displayed A
      OK is displayed B

      1. The Data List item "Oper Permission (Battery)" is judged OK or NG according to the values of the following Data List items.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Idling Stop Rate Rate of the idling stop time to the entire ignition switch ON time Min.: 0%, Max.: 100% - -

        Powertrain > Stop and Start > Data List
        Tester Display
        Idling Stop Rate
        Permission Criteria
        Tester Display Idling Stop Rate
        Oper Permission (Battery) 39% or less

        Tech Tips

        When the idling stop rate exceeds 40%, stop and start control is permitted when the rate drops to 37% or less.


    B
    A
  16. READ VALUE USING GTS (IDLING STOP RATE)

    Tech Tips

    Check the idling stop rate.


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Idling Stop Rate.

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Idling Stop Rate Rate of the idling stop time to the entire ignition switch ON time Min.: 0%, Max.: 100% - -

      Powertrain > Stop and Start > Data List
      Tester Display
      Idling Stop Rate
      Result
      Result Proceed to
      40% or higher A
      39% or less B

      Tech Tips

      When the idling stop rate exceeds 40%, turn the ignition switch off and then start the engine again. If NG is still displayed for the Data List item "Oper Permission (Battery)", the battery may be discharged or deteriorated. Check the battery condition and recharge or replace the battery.


    A
    B
  17. READ VALUE USING GTS (HOOD COURTESY SWITCH)

    Tech Tips

    Check the engine hood courtesy switch (hood lock assembly).


    1. Enter the following menus: Powertrain / Stop and Start / Data List / Hood Courtesy Switch.

    2. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Hood Courtesy Switch Hood courtesy switch signal ON / OFF

      ON: Engine hood closed

      OFF: Engine hood opened

      -

      Powertrain > Stop and Start > Data List
      Tester Display
      Hood Courtesy Switch
      Result
      Result Proceed to
      OK A
      NG B

      Tech Tips

      When the result is OK, the engine may have been started with the engine hood open to perform a jump start. Close the engine hood and start the engine again.


    A
    B
  18. READ VALUE USING GTS (INTEGRATED CURRENT)

    Tech Tips

    Judge the battery condition based on the integrated current value.


    1. Start the engine and allow it to idle.

    2. Enter the following menus: Powertrain / Stop and Start / Data List / Integrated Current.

    3. Check the following items on the GTS display.


      Powertrain > Stop and Start > Data List
      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Integrated Current Battery integrated current Min.: -268434.45 A-sec, Max.: 268435.45 A-sec Differs according to the vehicle condition (charge / discharge conditions) -

      Powertrain > Stop and Start > Data List
      Tester Display
      Integrated Current

      1. Judge whether the Data List item "Integrated Current" is OK or NG according to the following table.


        Powertrain > Stop and Start > Data List
        Tester Display Measurement Item Range Normal Condition Diagnostic Note
        Battery Temp (Start) Battery temperature at engine start Min.: -40°C (-40°F), Max.: 100°C (212°F) Same as temperature around battery at engine start (after engine start) -
        Idle Engine idling status ON / OFF

        ON: Accelerator pedal fully released

        OFF: Accelerator pedal depressed

        This is sent from the ECM.
        Battery Current Battery current Min.: 0 A, Max.: 124.99 A - -
        Ambient Temp Sensor Ambient temperature Min.: -30°C (-22°F), Max.: 50°C (122°F) Close to ambient air temperature -
        Integrated Current Battery integrated current Min.: -268434.45 A-sec, Max.: 268435.45 A-sec Differs according to the vehicle condition (charge / discharge conditions) -

        Powertrain > Stop and Start > Data List
        Tester Display
        Battery Temp (Start)
        Idle
        Battery Current
        Ambient Temp Sensor
        Integrated Current
        Standard Integrated Current Value
        Tester Display Integrated Current Battery Temperature Proceed to
        Integrated Current

        -6451 A-sec or less*1

        -4838 A-sec or less*2

        - A

        -5299 A-sec or less*1

        -3974 A-sec or less*2

        -10°C (14°F) or higher, or 65°C (149°F) or lower A
        70°C (158°F) or higher A or B

        -1152 A-sec or less*1

        -864 A-sec or less*2

        11°C (51.8°F) or higher, or 65°C (149°F) or lower A
        70°C (158°F) or higher A or B
        -0 A-sec or less -10°C (14°F) or higher, or 65°C (149°F) or lower A
        70°C (158°F) or higher A or B
        Cause and Action to be Taken
        Result Cause Action to be Taken
        A Integrated current value is limited for the stop and start control due to discharge or deterioration of the battery Check the battery condition and recharge or replace the battery
        B Integrated current value is limited for stop and start control due to battery temperature (too high/low) Leave the battery under room temperature conditions until its temperature becomes as specified. Then check the battery condition and recharge or replace the battery.

        • *1: for 1AD-FTV

        • *2: for 1ND-TV, 1NR-FE

        • After recharging the battery, initialize the integrated current value* and drive the vehicle until stop and start control operation is permitted (approximately 15 to 40 minutes).

          *: Disconnect the cables from the battery, wait for 30 seconds or more and then reconnect the cables.

        • When the battery sensor current value is normal, recharge or replace the battery

      Result
      Proceed to
      NEXT

    NEXT