GENERATOR(for 90A Type) REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE NO. 2 CYLINDER HEAD COVER

    Click here

  4. REMOVE V-RIBBED BELT

    Click here

  5. REMOVE GENERATOR ASSEMBLY


    1. A01LWMT

      Remove the terminal cap.

    2. Remove the nut and disconnect the wire harness from terminal B.

    3. Disconnect the connector and harness clamp.

    4. A01LY1Z

      Remove the 2 bolts and adjusting bar.

    5. A01M28V

      Remove the bolt and generator assembly.

    6. A01M1EB

      Remove the bolt and wire harness clamp bracket.