GENERATOR REMOVAL

PROCEDURE


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work.

    Click here

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

    Click here

  3. REMOVE FRONT DRIVE SHAFT ASSEMBLY RH

    Click here

  4. REMOVE V-RIBBED BELT

    Click here

  5. REMOVE GENERATOR ASSEMBLY


    1. A012MLE

      Remove the terminal cap.

    2. Disconnect the connector.

    3. Remove the nut and bolt, and disconnect the wire harness from terminal B.

    4. A012K1W

      Remove the 3 bolts and generator assembly.