DIFFERENTIAL PRESSURE SENSOR INSTALLATION

PROCEDURE


  1. INSTALL DIFFERENTIAL PRESSURE SENSOR ASSEMBLY


    1. A012G3VC01
      *1 Vacuum Transmitting Hose Assembly
      *2 No. 2 Vacuum Transmitting Hose Assembly
      *a Front of Vehicle
      *b Paint Mark (Yellow)
      *c Paint Mark (Red)
      *d LH Side
      *e Paint Mark

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly and slide the 2 clips to secure them.

      Note

      Connect the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly so that the paint marks of the vacuum transmitting hose assembly and No. 2 vacuum transmitting hose assembly are within the area shown in the illustration.

    2. A012IPM

      Install the differential pressure sensor assembly with the bolt.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. Connect the differential pressure sensor connector and wire harness clamp.

  2. INSTALL COWL TOP VENTILATOR LOUVER SUB-ASSEMBLY

    Click here