FUEL SEDIMENTER WARNING SWITCH INSPECTION

PROCEDURE


  1. INSPECT LEVEL WARNING SWITCH


    1. A00Y90OC01
      *a

      Component without harness connected

      (Level Warning Switch)

      Inspect the level warning switch.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Terminals Condition Resistance
        1 - 2 Float upper end position Below 0.5 Ω
        1 - 2 Float lower end position 1 MΩ or higher

        If the result is not as specified, replace the level warning switch.