PROCEDURE
INSTALL MASS AIR FLOW METER SUB-ASSEMBLY
Tech Tips
Perform "Air Flow Meter Learning Value Reset" after replacing the mass air flow meter sub-assembly.
Using a T20 "TORX" socket wrench, install the mass air flow meter sub-assembly to the air cleaner cap sub-assembly with the 2 screws.
Note
If the mass air flow meter sub-assembly has been struck or dropped, replace it.
Connect the mass air flow meter sub-assembly connector.
PERFORM INITIALIZATION
Perform "Air Flow Meter Learning Value Reset" after replacing the mass air flow meter sub-assembly.