PROCEDURE
INSTALL NO. 2 ECM BRACKET
Install the No. 2 ECM bracket to the ECM with the 2 screws.
INSTALL ECM BRACKET
Install the No. 1 ECM bracket to the ECM with the 2 screws.
INSTALL ECM
Install the ECM with the 2 bolts.
Note
If a component has been dropped or subjected to a strong impact, replace it.
Connect the 2 ECM connectors and lower the 2 levers.
Note
When connecting the connectors, make sure that dirt, water or other foreign matter does not contact the connecting parts of the connectors.
Make sure that the 2 levers are locked securely.
Install the wire harness clamp.
INSTALL NO. 1 AIR CLEANER INLET
Install the bolt.
INSTALL AIR CLEANER CASE SUB-ASSEMBLY
INSTALL AIR CLEANER CAP SUB-ASSEMBLY
INSTALL NO. 2 CYLINDER HEAD COVER
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected.