8NR-FTS STARTING SERVICE DATA

Starter Assembly (w/o Stop And Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V Below 90 A
Magnet Starter Switch Assembly (w/o Stop And Start System)
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 -Magnet switch body Below 1.5 Ω
Starter Armature Assembly (w/o Stop And Start System)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher
Commutator for runout Standard Runout 0.02 mm (0.000787 in.)
Maximum Runout 0.04 mm (0.00157 in.)
Commutator diameter Standard Diameter 29.9 mm (1.18 in.)
Minimum Diameter 28.8 mm (1.13 in.)
Undercut depth Standard Undercut Depth 0.9 mm (0.0354 in.)
Minimum Undercut Depth 0.4 mm (0.0157 in.)
Starter Brush Holder Assembly (w/o Stop And Start System)
Brush length Standard Length 10.5 mm (0.413 in.)
Minimum Length 7.0 mm (0.276 in.)
Tester Connection Condition Specified Condition

A - B

A - C

B - D

C - D

Always 10 kΩ or higher

A - D

B - C

Below 1 Ω
Starter Assembly (for Transaxle CVT with Stop and Start System and Transaxle M/T with Stop and Start System)
Tester Connection Condition Specified Condition
Battery positive (+) terminal - Terminal 30 - Terminal 50 11.5 V Below 90 A
Starter Armature Assembly (for Transaxle CVT with Stop and Start System and Transaxle M/T with Stop and Start System)
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω
Segment - Starter armature core 10 kΩ or higher
Commutator for runout Maximum Runout 0.05 mm (0.00197 in.)
Commutator diameter Standard Diameter 29 mm (1.1417 in.)
Minimum Diameter 28 mm (1.1024 in.)
Undercut depth Standard Undercut Depth 0.7 mm (0.0276 in.)
Minimum Undercut Depth 0.4 mm (0.0157 in.)
Starter Brush Holder Assembly (for Transaxle CVT with Stop and Start System and Transaxle M/T with Stop and Start System)
Brush length Standard Length 10.5 mm (0.413 in.)
Minimum Length 7.0 mm (0.276 in.)
Tester Connection Condition Specified Condition

A - B

A - C

B - D

C - D

Always 10 kΩ or higher

A - D

B - C

Below 1 Ω
Brush spring load Standard Spring Load 22.3 to 27.3 N (2.27 to 2.78 kgf, 5.01 to 6.14 lbf)
Minimum Spring Load 13.8 N (1.41 kgf, 3.1 lbf)
Magnet Starter Switch Assembly (for Transaxle CVT with Stop and Start System and Transaxle M/T with Stop and Start System)
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω
Terminal 50 -Magnet starter switch assembly body Below 2 Ω
Engine Switch
Tester Connection Condition Specified Condition
5 (SS1) - 6 (AGND) Not pushed 10 kΩ or higher
1 (SS2) - 6 (AGND)
5 (SS1) - 6 (AGND) Pushed Below 1 Ω
1 (SS2) - 6 (AGND)
Condition Specified Condition

Battery positive (+) → Terminal 9 (SWIL)

Battery negative (-) → Terminal 6 (AGND)

Illuminates
Ignition or starter switch assembly
Tester Connection Condition Specified Condition
Between all terminals LOCK 1 MΩ or higher
5 (AM1) - 7 (ACC) ACC Below 1 Ω
5 (AM1) - 7 (ACC) - 8 (IG1) ON Below 1 Ω
3 (IG2) - 4 (AM2)
5 (AM1) - 6 (ST1) - 8 (IG1) START Below 1 Ω
2 (ST2) - 3 (IG2) - 4 (AM2)
ST relay
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω