| Condition | Specified Condition |
|---|---|
| Standard valve opening temperature | 100 °C (212 °F) |
| Item | Condition | Specified Condition |
|---|---|---|
| Cooling fan motor | Battery voltage applied at 20°C (68°F) | 12.2 to 15.7 A |
| No. 2 cooling fan motor | Battery voltage applied at 20°C (68°F) | 11.7 to 15.2 A |
| Item | Condition | Specified Condition |
|---|---|---|
| Reserve tank cap | Standard pressure (for brand-new reserve tank cap) |
93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi) |
| Minimum pressure (for used reserve tank cap) |
79 kPa (0.8 kgf/cm2, 11.5 psi) |
| Item | Tester Connection | Condition | Specified Condition |
|---|---|---|---|
| FAN NO. 1 relay | 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| FAN NO. 2 relay | 3 - 4 | Battery voltage not applied between terminals 1 and 2 | Below 1 Ω |
| Battery voltage applied between terminals 1 and 2 | 10 kΩ or higher | ||
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher | |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω | ||
| FAN NO. 3 relay | 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| Capacity | Classification |
|---|---|
| w/o Combustion Type Power Heater: 7.0 liters (7.4 US qts, 6.2 Imp. qts) | Toyota recommends the use of approved "Toyota Premium Long Life Coolant for 1WW engines" or equivalent. |
| w/ Combustion Type Power Heater: 7.3 liters (7.7 US qts, 6.4 Imp. qts) |