| Thermostat | Standard Valve Opening Temperature | 80 to 84°C (176 to 183°F) |
| Standard Valve Lift | 10 mm (0.39 in.) or more at 82°C (180°F) | |
| Cooling fan motor | 7.4 to 10.9 A (Battery voltage applied at 20°C (68°F)) |
|
| FAN NO. 1 relay | 3-5 | 10 kΩ or higher (Battery voltage not applied between terminals 1 and 2) |
| 3-5 | Below 1Ω (Battery voltage applied between terminals 1 and 2) |
|
| Reserve tank cap | Standard valve (for brand-new cap) | 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi) |
| Minimum standard valve (for used cap) | 78 kPa (0.8 kgf/cm2, 11.3 psi) |
|
| Capacity | Classification |
|---|---|
| for CVT: 5.8 liters (6.1 US qts, 5.1 Imp. qts) for manual transaxle: 5.6 liters (5.9 US qts, 4.9 Imp. qts) |
Use only "TOYOTA Super Long Life Coolant", or similar high qualityethylene glycol based non-silicate, non-amine, non-nitrite, and nonboratecoolant with long-life hybrid organic acid technology (coolantwith long-life hybrid organic acid technology is a combination of lowphosphates and organic acids). |