8NR-FTS INTAKE / EXHAUST SERVICE DATA

COOLANT
Standard Capacity Classification
2.1 liters (2.2 US qts, 1.8 Imp. qts) Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).
TURBOCHARGER
Boost pressure Standard

120 kPa (1.2 kgf/cm2, 17 psi) or higher

Turbine with valve housing sub-assembly Warpage Standard 0.15 mm (0.00591 in.) or less
Waste gate valve Clearance Standard 0.15 mm (0.00591 in.)
Turbine shaft Axial play Standard 0.15 mm (0.00591 in.) or less
Waste gate valve actuator Travel Standard 15 mm (0.591 in.) or more
Intake air control valve (air by-pass valve assembly) Tester Connection 1 - 2
Condition 20°C (68°F)
Specified Condition 8.7 to 9.2 Ω
EXHAUST PIPE
Compression spring Exhaust manifold converter sub-assembly (TWC: Front Catalyst) x Front exhaust pipe sub-assembly (TWC: Rear Catalyst) Standard length 43 mm (1.69 in.)
Minimum free length 41.5 mm (1.63 in.)
Front exhaust pipe sub-assembly (TWC: Rear Catalyst) x Tail exhaust pipe assembly Standard length 40 mm (1.57 in.)
Minimum free length 38.5 mm (1.52 in.)
RESERVE TANK CAP (for Intercooler)
Item Specified Condition
Standard pressure (for brand-new reserve tank cap (for Intercooler))

93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18 psi)

Minimum pressure (for used reserve tank cap (for Intercooler))

79 kPa (0.8 kgf/cm2, 11.5 psi)