| Fuel pressure | Normal condition | 27000 to 45000 kPa (Idling) |
| Target common rail pressure | Normal condition | 32000 to 200000 kPa (engine running) |
| Supply pump assembly (Suction control valve assembly) |
Standard resistance | 1.9 to 2.3 Ω at 20°C (68°F) |
| Common rail assembly (Fuel pressure sensor) |
Tester Connection 5 (PR) - 4 (E2) |
16.4 kΩ or less |
| Tester Connection 2 (PR2) - 3 (E2S) |
16.4 kΩ or less | |
| Tester Connection 6 (VC) - 5 (PR) |
3 kΩ or less | |
| Tester Connection 1 (VCS) - 2 (PR2) |
3 kΩ or less | |
| Common rail (Pressure control valve) |
Tester Connection 1 - 2 |
0.96 to 1.16 Ω at 20°C (68°F) |
| Fuel temperature sensor | Standard resistance | 2.32 to 2.59 kΩ at 20°C (68°F) |
| 0.310 to 0.326 kΩ at 80°C (176°F) | ||
| Fuel sender gauge assembly | Standard resistance | 12.0 to 18.0 Ω (Float level F) |
| 12.0 to 415.0 Ω (Float level E to F) | ||
| 405.0 to 415.0 Ω (Float level E) | ||
| Level warning switch | Standard resistance (Float upper end position) |
Below 0.5 Ω |
| Standard resistance (Float lower end position) |
1 MΩ or higher |