CANISTER INSPECTION

PROCEDURE


  1. CHECK CANISTER (FUEL SUCTION PLATE SUB-ASSEMBLY)


    1. Inspect the ventilation of the canister (fuel suction plate sub-assembly).


      1. A012K18C01
        *a Port A
        *b Port B
        *c Port C
        *d Air

        Close the port (B), apply compressed air to the port (A) and check that the air flows out from the port (C).

    2. Inspect the check valve.


      1. A012F4JC04
        *a Port A
        *b Port B
        *c Port C
        *d Air

        Close the port (C), apply compressed air to the port (A) and check that the air flows out from the port (B).

      2. A012FVJC01
        *a Port A
        *b Port B
        *c Port C

        Using a vacuum pump, apply vacuum to the port (A) with the port (C) closed.

        OK
        The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches the specified level.