| DTC Code | DTC Name |
|---|---|
| B1830/57 | Short in Curtain Shield Squib RH Circuit |
| B1831/57 | Open in Curtain Shield Squib RH Circuit |
| B1832/57 | Short to GND in Curtain Shield Squib RH Circuit |
| B1833/57 | Short to B+ in Curtain Shield Squib RH Circuit |
DESCRIPTION
The curtain shield squib RH circuit consists of the center airbag sensor and curtain shield airbag RH.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib RH circuit.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1830/57 | One of the following conditions is met:
|
|
| B1831/57 | One of the following conditions is met:
|
|
| B1832/57 | One of the following conditions is met:
|
|
| B1833/57 | One of the following conditions is met:
|
|
WIRING DIAGRAM
| *a | Curtain Shield Squib RH |
| *b | Center Airbag Sensor |
CAUTION / NOTICE / HINT
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected Click here.
Tech Tips
To perform the simulation method, enter check mode (signal check) with the intelligent tester (See page ), and then wiggle each connector of the airbag system or drive the vehicle on various types of roads Click here.
PROCEDURE
CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH)
| *1 | Curtain Shield Squib RH |
| *2 | Center Airbag Sensor |
| *3 | Front view of wire harness connector (to Curtain Shield Squib RH) |
| *4 | Connector C |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connector from the curtain shield airbag RH.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
CAUTION:
Never connect the tester to the curtain shield airbag RH (curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.
Note
Do not forcibly insert SST into the terminals of the connector when connecting SST.
Insert SST straight into the terminals of the connector.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs Click here.
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs Click here.
| OK |
|---|
| DTC B1830, B1831, B1832 or B1833 is not output. |
Tech Tips
Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.
| OK |
|
REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH Click here |
| NG |
|
CHECK CONNECTOR
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the No. 2 floor wire connector (on the curtain shield airbag RH side) is not damaged.
| OK |
|---|
| The lock button is not disengaged, and the claw of the lock is not deformed or damaged. |
| NG |
|
REPLACE NO. 2 FLOOR WIRE |
| OK |
|
CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT)
| *1 | Curtain Shield Squib RH |
| *2 | No. 2 Floor Wire |
| *3 | Center Airbag Sensor |
| *4 | Front view of wire harness connector (to Curtain Shield Squib RH) |
| *5 | Connector C |
Disconnect the connectors from the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
Release the activation prevention mechanism built into connector B Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE NO. 2 FLOOR WIRE |
| OK |
|
CHECK CENTER AIRBAG SENSOR
| *1 | Curtain Shield Squib RH |
| *2 | Center Airbag Sensor |
Connect the connectors to the curtain shield airbag RH and center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs Click here.
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs Click here.
| OK |
|---|
| DTC B1830, B1831, B1832 or B1833 is not output. |
Tech Tips
Codes other than DTC B1830, B1831, B1832 and B1833 may be output at this time, but they are not related to this check.
| OK |
|
USE SIMULATION METHOD TO CHECK Click here |
| NG |
|
REPLACE CENTER AIRBAG SENSOR ASSEMBLY Click here |