NETWORK GATEWAY ECU(for RHD) INSTALLATION

PROCEDURE


  1. INSTALL NETWORK GATEWAY ECU


    1. Install the network gateway ECU with the bolt.

      Torque:
      12 N*m  { 122 kgf*cm, 9 ft.*lbf }
    2. Connect the connector.

  2. INSTALL FUSE BOX OPENING COVER

    Click here

  3. INSTALL NO. 2 SWITCH HOLE BASE

    Click here

  4. INSTALL COWL SIDE TRIM BOARD RH

    Click here

  5. INSTALL FRONT DOOR SCUFF PLATE RH

    Click here