GENERATOR INSPECTION

PROCEDURE


  1. INSPECT BRUSH


    1. A002OEUE02
      Text in Illustration
      *a Exposed Length

      Using a vernier caliper, measure the length of the exposed brushes.

      Standard exposed length
      11.2mm (0.441 in.)
      Minimum exposed length
      2.0 mm (0.0787 in.)

      If the exposed length is less than the minimum, replace the generator regulator assembly.