ECD SYSTEM(for Swirl Control Valve) Cranking Holding Function Circuit

DESCRIPTION


WIRING DIAGRAM

A002OZDE09

CAUTION / NOTICE / HINT

Note


  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

  • When replacing the ECM, the ECM needs Registration and Initialization Click here.

Tech Tips


  • When the ECM must be replaced, before replacing the ECM, perform the "Learning Values Save" function using the GTS. Then after installing the new ECM, perform all of the initialization/registrations for the "Learning Values Write" function by following the instructions shown on the GTS display.

  • This chart is based on the premise that the engine can crank normally. If the engine cannot crank normally, proceed to Problem Symptoms Table Click here.

PROCEDURE


  1. READ VALUE USING GTS (STARTER SIGNAL)


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.

    5. Check the value displayed on the GTS when the ignition switch is turned to the ON and START positions.

      OK
      Ignition Switch Position Starter Signal
      ON OFF
      START ON

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (ECM - ST RELAY HOLDER)

    A002M4XE03

    1. Disconnect the ECM connector.

    2. Remove the ST relay from the No. 3 relay block.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A76-36 (STA) - 2 (ST relay holder) Always Below 1 Ω
      Text in Illustration
      *1 No. 3 Relay Block *2 ST Relay Holder
      *a

      Front view of wire harness connector

      (to ECM)

      - -

    OK
    NG