STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY INSPECTION

PROCEDURE


  1. INSPECT STOP AND START SYSTEM CANCEL SWITCH ASSEMBLY


    1. A002OG5E03
      Text in Illustration
      *a

      Component without harness connected

      (Stop and Start System Cancel Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      6 (ECU) - 3 (E) Pushed Below 1 Ω
      6 (ECU) - 3 (E) Not pushed 10 kΩ or higher

      If the result is not as specified, replace the stop and start system cancel switch assembly.

    2. A002OG5E04
      Text in Illustration
      *a

      Component without harness connected

      (Stop and Start System Cancel Switch Assembly)

      Apply battery voltage between the terminals of the switch, and check the illumination condition of the stop and start system cancel switch assembly.

      OK
      Measurement Condition Specified Condition

      Battery positive (+) - Terminal 5 (ILL+)

      Battery negative (-) - Terminal 4 (ILL-)

      Illuminates

      If the result is not as specified, replace the stop and start system cancel switch assembly.